Diabetes technology

Continuous glucose monitoring using the FreeStyle Libre Pro iQ in presymptomatic type 1 diabetes

DiabetologiaPublished Diagnostic accuracy study

Authors' conclusion

These findings support CGM as a promising tool for staging and risk stratification in early-stage type 1 diabetes, while highlighting the need for system-specific interpretation before use in therapeutic decision-making.

Study context

Population
Children and adolescents without islet autoantibodies or with early-stage (stage 1 or 2) T1D, December 2023 to December 2025; median age 10.0 years (IQR 7.9–12.8), 73 female among analysed126 analysed
Participants
50 / 45 / 25
Comparison
FreeStyle Libre Pro iQ continuous glucose monitoring (CGM) in control, stage 1 and stage 2 type 1 diabetes; comparison with Dexcom G6
  • Controln = 50reference
  • Stage 1n = 45
  • Stage 2n = 25
Outcome
≥1 CGM parameter exceeding 97.5th percentile of control values
Methodological detailsCGM data unavailable or incomplete for 13 participants (9%)
  • CGM data unavailable or incomplete for 13 participants (9%)

Performance

As reported in the abstract

P = 0.017

Further findings

OutcomeStage 1Stage 2P value
≥2 CGM parameters exceeding 97.5th percentile thresholdStage 2 vs Stage 113%44%P = 0.0077
TA140 >15% (97.5th percentile threshold)0 events40%
TA140 >15% (97.5th percentile threshold) — Progressed to clinical diabetes within 1 year exceeding TA140 threshold (rapid progressors)
6 of 8
  • Sensitivity for progression to clinical diabetes within 1 year (97.5th percentile of control values): FreeStyle Libre Pro iQ 75% to 100% · sensitivity 75% to 100%
  • Sensitivity for progression to clinical diabetes within 1 year (97.5th percentile of control values): Dexcom G6 50% to 100% · sensitivity 50% to 100%

Sensitivity for progression to clinical diabetes within 1 year (97.5th percentile of control values)

FreeStyle Libre Pro iQ values differed markedly from those previously observed with Dexcom G6 in a similar cohort

Original publication

Continuous glucose monitoring using the FreeStyle Libre Pro iQ in presymptomatic type 1 diabetes. Diabetologia. Published 7 September 2026. doi:10.1007/s00125-026-06852-w