Diabetes technology

The Associations of Mean Glucose and Time in Range from Continuous Glucose Monitoring with HbA1c in Adults with Type 2 Diabetes

Diabetes Technol TherPublished Secondary analysis of the HYPNOS randomised trial

Authors' conclusion

Mean glucose and HbA1c are strongly correlated in type 2 diabetes patients not taking insulin but discordance is evident at the individual level.

Study context

Population
Adults with T2D in the Hyperglycemic Profiles in Obstructive Sleep Apnea (HYPNOS) trial, wearing Dexcom G4 and Abbott Libre Pro continuous glucose monitoring (CGM) sensors simultaneously up to 4 weeks
Participants
186 adults

Primary result

As reported in the abstract

Pearson's correlation of HbA1c with CGM TIR, Abbott
−0.79
Pearson's correlation of HbA1c with CGM TIR, Dexcom
−0.81
Pearson's correlation of HbA1c with CGM mean glucose, Dexcom
0.84
Pearson's correlation of HbA1c with CGM mean glucose, Abbott
0.82
Differences in CGM mean glucose at any given HbA1c value
±20 mg/dL
Differences in CGM TIR at any given HbA1c value
±14%

Further findings

Mean HbA1c (SD 1.3)
7.7%

Original publication

The Associations of Mean Glucose and Time in Range from Continuous Glucose Monitoring with HbA1c in Adults with Type 2 Diabetes. Diabetes Technol Ther. Published 23 November 2022. doi:10.1089/dia.2022.0178