Diabetes technology

Real-World Ketone Testing Patterns Among People Using FreeStyle Libre

Diabetes Technol TherPublished Retrospective real-world data analysis

Authors' conclusion

Most readers did not demonstrate adherence to standard-of-care recommendations for ketone monitoring and infrequently recheck ketones after elevated readings. Incorporation of continuous ketone monitoring into FSL would address limitations with current ketone testing methodologies and adherence to ketone monitoring guidelines.

Study context

Population
Individuals using a FreeStyle Libre (FSL) reader and blood ketone test strips, real-world data September 2014 to September 2024>2.5 million ketone readings
Exposure
≤0.5 mmol/L vs 0.6-1.4 mmol/L vs 1.5-2.9 mmol/L vs ≥3.0 mmol/L
Outcome
Ketone testing patterns
Methodological detailsanalysis by reader
  • Analysis by reader

Main finding

As reported in the abstract

Readers that never recorded a ketone test

92.4%

Readers that performed a ketone test when glucose exceeded 250 mg/dL

5%

Observational data: associations, not effects.

Further findings

Glucose in the 24 h before the ketone test

Users with ketones ≥3.0 mmol/L had higher glucose concentrations in the preceding 24 h

Timing of ketone testing and retesting, ketones ≥1.5 mmol/L

Ketone testing typically delayed after glucose surpassed 250 mg/dL
5-8 h
Retesting ketones within 24-72 h was rare

Original publication

Real-World Ketone Testing Patterns Among People Using FreeStyle Libre. Diabetes Technol Ther. Published 11 May 2026. doi:10.1177/15209156261446059