Diabetes technology

Real-world evidence supporting the use of advanced hybrid closed loop in poorly controlled type 1 diabetes patients

Diabetes Res Clin PractPublished Retrospective cohort study

Authors' conclusion

Our findings support a-HCL utilization across all patients, particularly in poorly controlled type 1 diabetes patients.

Study context

Population
T1D patients at University Hospital Zurich, Switzerland, who transitioned from predictive low glucose suspension (PLGS) or standard hybrid closed-loop (s-HCL) to advanced hybrid closed loop (a-HCL) between January 2020 and December 2021
Participants
71 patients
Exposure
Advanced HCL vs prior PLGS or standard HCL
Outcome
Glycemic metrics pre vs post a-HCL
Methodological detailssingle-centre, pre-post comparison
  • Single-centre
  • Pre-post comparison

Main finding

As reported in the abstract

HbA1c, pre-a-HCL vs post-a-HCL (mean ± SD; p < 0.001)

7.2 ± 0.9 % to 6.8 ± 0.5 %

Sensor glucose (SG), pre-a-HCL vs post-a-HCL (mean ± SD; p < 0.001)

8.8 ± 1.4 mmol/L to 7.8 ± 0.8 mmol/L

Time above range (TAR), pre-a-HCL vs post-a-HCL (p < 0.001)

26.3 % to 17.3 %

Time in range (TIR), pre-a-HCL vs post-a-HCL (p < 0.001)

68.5 % to 79.8 %

Observational data: associations, not effects.

Further findings

Subgroups with greatest improvement

Improvements most pronounced with higher baseline HbA1c, SG, coefficient of variation (CV) and lower TIR, and BMI > 30 kg/m²

Original publication

Real-world evidence supporting the use of advanced hybrid closed loop in poorly controlled type 1 diabetes patients. Diabetes Res Clin Pract. Published 8 February 2025. doi:10.1016/j.diabres.2025.112035

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.