Type 1 diabetes

Generating real‐world evidence on diabetes technology using the CareLink Personal data management system

Diabetes Obes MetabPublished Methodological study

Authors' conclusion

RWE from CP adheres to the principles of RWE and can serve as robust evidence on the performance and safety of MiniMed systems.

Study context

Population
MiniMed system users with CareLink Personal (CP) accounts; last year's MiniMed 780G system data as case study
Outcome
CP fitness-for-research metrics
Follow-up
Last year
Methodological detailsreal-world database validation, case study of MiniMed 780G system data
  • Real-world database validation
  • Case study of MiniMed 780G system data

Performance

As reported in the abstract

Users with a CP account
Over 95%
Users providing consent
96%
Usable share of census population
>91%
Endpoints included in CP
>50
Mean data points per person per day (maximum 288, 5-min intervals)
263
Automated uploads
Ninety-nine per cent
Users with a data gap >1 day
1 in 6
Users with a data gap >1 week
1 in 50

Original publication

Generating real‐world evidence on diabetes technology using the CareLink Personal data management system. Diabetes Obes Metab. Published 4 September 2024. doi:10.1111/dom.15868

Composed by AI from the published abstract and checked against it. How Briefs are made →