Diabetes technology

Continuous glucose monitoring-derived time in range and CV are associated with altered tissue characteristics of the carotid artery wall in people with type 2 diabetes

DiabetologiaPublished Exploratory analysis of a prospective observational cohort study

Authors' conclusion

TIR and CV were significantly associated with changes in the tissue characteristics of the carotid artery wall.

Study context

Population
People with T2D and no apparent history of symptomatic CVD, undergoing continuous glucose monitoring (CGM) and carotid US (intima-media thickness (IMT), grey-scale median (GSM)) at baseline and 104 weeks
Participants
600 people
Comparison
CGM-derived time in range (TIR) and CV vs changes in carotid atherosclerosis indices
Primary endpoint
Association of CGM-derived indices, mainly TIR and CV, with changes in carotid atherosclerosis index values
Follow-up
104 weeks
Methodological detailsmulticentre
  • Multicentre

Primary result

As reported in the abstract

Mean GSM: regression coefficient per 10% increase in TIR

0.52

95% CI 0.06, 0.98; Hochberg-adjusted p value 0.038

Mean GSM: regression coefficient per 1% increase in CV

−0.12

95% CI −0.22, −0.02; Hochberg-adjusted p value 0.038

Thickened-lesion GSM: regression coefficient per 10% increase in TIR

0.95

95% CI 0.12, 1.79; Hochberg-adjusted p value 0.038

Thickened-lesion GSM: regression coefficient per 1% increase in CV

−0.19

95% CI −0.36, −0.01; Hochberg-adjusted p value 0.038

Further findings

OutcomeTargets achievedTargets not achievedP value
Annual change in mean GSM by achievement of consensus target CGM-derived metrics at baseline0.94 ± 6.88 units/year−0.21 ± 6.19 units/yearP = 0.007

Change in carotid indices from baseline to 104 weeks

Mean IMT
from 0.759±0.153 to 0.773±0.152 mm, p<0.001
Thickened-lesion GSM
from 43.5±19.5 to 53.9±23.5 units, p<0.001
Common carotid artery maximum-IMT
from 1.109±0.442 to 1.116±0.469 mm, p=0.453
Mean GSM
from 48.7±19.3 to 49.8±20.8 units, p=0.092

Original publication

Continuous glucose monitoring-derived time in range and CV are associated with altered tissue characteristics of the carotid artery wall in people with type 2 diabetes. Diabetologia. Published 26 September 2023. doi:10.1007/s00125-023-06013-3

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.