Type 1 diabetes

Sustained Glycemic Outcomes with the MiniMed ™ 780G System: Real-World Evidence from >16,000 Users Across 18 Latin American Countries Over Two Years

Diabetes Technol TherPublished Real-world observational study

Authors' conclusion

The MiniMed™ 780G AHCL system delivered consistent and durable glycemic control over 24 months across the full demographic and structural heterogeneity of Latin America. Performance was aligned with internationally recommended consensus targets and was independent of age, sex, country, and health care infrastructure.

Study context

Population
Individuals with T1D using the MiniMed 780G advanced hybrid closed-loop (AHCL) system, 18 Latin American countries, January 2020–October 2025; 27.1% pediatric (<16 years), 70.8% adult (≥16 years)1,204 in longitudinal sub-analysis
Participants
16,669 individuals
Exposure
Overall vs ROS
  • Overalln = 16,669
Outcome
TIR, time in tight range (TITR), GMI and TBR, stratified by age, sex, country and ROS
Methodological detailsmultinational, retrospective device data analysis, longitudinal sub-analysis
  • Multinational
  • Retrospective device data analysis
  • Longitudinal sub-analysis

Main finding

As reported in the abstract

TIR, GMI and target attainment
GroupValueMean glucose management indicator (GMI)Time in range (TIR) > 70% attainmentComposite target (GMI < 7, TIR > 70, TB70 < 4, TB54 < 1) attainmentMean TIR with ROSMean time in tight range (TITR) with ROSTITR overallTITR with ROS
Overallmean 73.4%6.9%
ROSmean 77.5%83.9%66.4%
Pediatricmean 70.0%74.2%51.2%
Adultmean 74.6%50.3%54.1%

Value

Overallmean 73.4%
ROSmean 77.5%
Pediatricmean 70.0%
Adultmean 74.6%

Mean glucose management indicator (GMI)

Overall6.9%
ROS— not stated in the abstract
Pediatric— not stated in the abstract
Adult— not stated in the abstract

Time in range (TIR) > 70% attainment

Overall— not stated in the abstract
ROS83.9%
Pediatric— not stated in the abstract
Adult— not stated in the abstract

Composite target (GMI < 7, TIR > 70, TB70 < 4, TB54 < 1) attainment

Overall— not stated in the abstract
ROS66.4%
Pediatric— not stated in the abstract
Adult— not stated in the abstract

Mean TIR with ROS

Overall— not stated in the abstract
ROS— not stated in the abstract
Pediatric74.2%
Adult— not stated in the abstract

Mean time in tight range (TITR) with ROS

Overall— not stated in the abstract
ROS— not stated in the abstract
Pediatric51.2%
Adult— not stated in the abstract

TITR overall

Overall— not stated in the abstract
ROS— not stated in the abstract
Pediatric— not stated in the abstract
Adult50.3%

TITR with ROS

Overall— not stated in the abstract
ROS— not stated in the abstract
Pediatric— not stated in the abstract
Adult54.1%
ROS adopted by users
19.2%

Observational data: associations, not effects.

Further findings

Durability of TIR (longitudinal sub-analysis) · 24 consecutive monthly time points

TIR remained clinically stable within one and a half percentage points in both age groups

Original publication

Sustained Glycemic Outcomes with the MiniMed ™ 780G System: Real-World Evidence from >16,000 Users Across 18 Latin American Countries Over Two Years. Diabetes Technol Ther. Published 19 September 2026. doi:10.1177/15209156261486558

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.