Thyroid disease

Modified American College of Radiology Thyroid Imaging Reporting and Data System and Modified Artificial Intelligence Thyroid Imaging Reporting and Data System for Thyroid Nodules: A Multicenter Retrospective Study

ThyroidPublished Diagnostic accuracy study

Authors' conclusion

The revised FNA thresholds and the stratification criteria of the mACR TI-RADS and mAI TI-RADS may be associated with improvements in specificity and accuracy, without significantly sacrificing sensitivity for malignancy detection.

Study context

Population
Thyroid nodules on US with definite pathological diagnoses, 6 Chinese hospitals, January 2017 to September 2021nodules in 2511 patients
Participants
2,596 participants
Comparison
Modified American College of Radiology (ACR) Thyroid Imaging Reporting and Data System (TI-RADS) and modified artificial intelligence (AI) TI-RADS vs original ACR TI-RADS
Outcome
Diagnostic performance and unnecessary FNA rate (UFR)
Methodological detailsmulticentre, retrospective
  • Multicentre
  • Retrospective

Performance

As reported in the abstract

Test or modelSpecificityAccuracyAUCUnnecessary FNA rate (UFR)Sensitivity
Modified ACR (mACR) TI-RADS73%74%0.8025%87%
Modified AI (mAI) TI-RADS73%75%0.8124%89%
Original ACR TI-RADS46%51%0.7048%93%

Specificity

Modified ACR (mACR) TI-RADS73%
Modified AI (mAI) TI-RADS73%
Original ACR TI-RADS46%

Accuracy

Modified ACR (mACR) TI-RADS74%
Modified AI (mAI) TI-RADS75%
Original ACR TI-RADS51%

AUC

Modified ACR (mACR) TI-RADS0.80
Modified AI (mAI) TI-RADS0.81
Original ACR TI-RADS0.70

Unnecessary FNA rate (UFR)

Modified ACR (mACR) TI-RADS25%
Modified AI (mAI) TI-RADS24%
Original ACR TI-RADS48%

Sensitivity

Modified ACR (mACR) TI-RADS87%
Modified AI (mAI) TI-RADS89%
Original ACR TI-RADS93%
  • mACR TI-RADS vs Original ACR TI-RADS: all p < 0.001 — higher specificity, accuracy, AUC; lower UFR with mACR
  • mACR TI-RADS vs Original ACR TI-RADS: P = 0.057 — slightly decreased with mACR
  • mAI TI-RADS vs Original ACR TI-RADS: all p < 0.001 — higher specificity, accuracy, AUC; lower UFR with mAI
  • mAI TI-RADS vs Original ACR TI-RADS: P = 0.13 — tended to be slightly decreased with mAI
  • Between mACR TI-RADS and mAI TI-RADS: all p > 0.05 — no significant difference

Original publication

Modified American College of Radiology Thyroid Imaging Reporting and Data System and Modified Artificial Intelligence Thyroid Imaging Reporting and Data System for Thyroid Nodules: A Multicenter Retrospective Study. Thyroid. Published 7 December 2023. doi:10.1089/thy.2023.0429

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.