Fully automated closed-loop insulin delivery in adults with type 2 diabetes: an open-label, single-center, randomized crossover trial
Primary result · TIR 3.9-10.0 mmol/lResult — go to the resultMean difference 35.3 percentage points 95% CI 28.0–42.6Authors' conclusion
Fully closed-loop insulin delivery improved glucose control without increasing hypoglycemia compared with standard insulin therapy
Study context
- Population
- Adults with T2D (7 women, 19 men; mean age 59 ± 11 years; baseline HbA1c 75 ± 15 mmol/mol (9.0% ± 1.4%))28 randomized
- Participants
- 26 adults
- Comparison
- CamAPS HX fully closed-loop app vs standard insulin therapy with masked glucose sensor (control)
- Primary endpoint
- Proportion of time in target glucose range (3.9-10.0 mmol/l)
- Follow-up
- 8-week periods
Methodological detailsopen-label, single-centre, two 8-week periods, 2-week to 4-week washout, Recruited 16 December 2020 to 24 November 2021; 30 recruited, 28 randomized (14 closed-loop first, 14 control first)
- Open-label
- Single-centre
- Two 8-week periods
- 2-week to 4-week washout
- Recruited 16 December 2020 to 24 November 2021; 30 recruited, 28 randomized (14 closed-loop first, 14 control first)
Primary result
TIR 3.9-10.0 mmol/l
Mean difference
35.3 percentage points
95% CI 28.0–42.6
P < 0.001
By group
Closed-loopvs Control
mean difference 35.3 percentage points (95% CI 28.0–42.6); P < 0.001
As reported in the abstract
Further findings
| Outcome | Closed-loop | Control | Mean difference (percentage points) (95% CI) | P value | |
|---|---|---|---|---|---|
| Time >10.0 mmol/l | 33.2% (SD 14.8%) | 67.0% (SD 25.2%) | −35.2 (−42.8 to −27.5) | P < 0.001 | |
| −60−40−20020Difference, percentage points (linear scale) |
Mmol l-1
| Outcome | Closed-loop | Control | Mean difference (mmol l-1) (95% CI) | P value | |
|---|---|---|---|---|---|
| Mean glucose | 9.2 (SD 1.2) | 12.6 (SD 3.0) | −3.6 (−4.6 to −2.5) | P < 0.001 | |
| −6−4−202Difference, mmol l-1 (linear scale) |
HbA1c · end of period
mean difference (mmol mol-1) −15 (−11 to −20) · P < 0.001
HbA1c % Closed-loop 7.3% ± 0.8% · Control 8.7% ± 1.2%
- HbA1c: estimate outside printed interval order; % MD −1.4 (95% CI −1.0 to −1.8)
Safety
Median
| Outcome | Closed-loop | Control | P value |
|---|---|---|---|
| Time <3.9 mmol/lSimilar between treatments | 0.44% (IQR 0.19–0.81%) | 0.08% (IQR 0.00–1.05%) | P = 0.43 |
Severe hypoglycaemia and SAEs
- Severe hypoglycemia events in either period
- 0
- Treatment-related serious adverse event during closed-loop period
- 1
Original publication
Fully automated closed-loop insulin delivery in adults with type 2 diabetes: an open-label, single-center, randomized crossover trial. Nat Med. Published 11 January 2023. doi:10. 1038/ s41591-022-02144-z
Composed by AI from the published abstract and checked against it. How Briefs are made →