Diabetes technology

Distribution of Oxygen Partial Pressures in Native Capillary Fingertip Blood Samples From a Large Diabetes Patient Population

J Diabetes Sci TechnolPublished Descriptive study

Authors' conclusion

This data set, unique in terms of size, gathered more than 14 years at four separate clinical sites, provides a robust and comprehensive representation of an unmanipulated pO2 fingertip capillary sample distribution, which should be of interest for physiological reasons, but also from a medical device development perspective, in which the effect of pO2 on device performance may be an important design consideration.

Study context

Population
Large diabetes population; nonarterialized fingertip capillary blood samples gathered during clinical surveillance by a blood glucose monitoring (BGM) system manufacturer28,533 pO2 values
Outcome
pO2 in nonarterialized fingertip capillary blood samples
Methodological detailsroutine clinical surveillance data, 4 clinical sites, more than 14 years, Data gathered over more than 14 years at 4 clinical sites
  • Routine clinical surveillance data
  • 4 clinical sites
  • More than 14 years
  • Data gathered over more than 14 years at 4 clinical sites

Main finding

As reported in the abstract

Mean pO2 (SD; range)

75.3 mm Hg

SD 10.6 mm Hg; range 27.7 to 151.5 mm Hg

Original publication

Distribution of Oxygen Partial Pressures in Native Capillary Fingertip Blood Samples From a Large Diabetes Patient Population. J Diabetes Sci Technol. Published 19 May 2022. doi:10.1177/19322968221095055

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.