Type 1 diabetes

Distribution of Hypo- and Hyperglycemic Event Duration in Type 1 Diabetes Using Automated Insulin Delivery

J Diabetes Sci TechnolPublished Retrospective comparative study of CGM data

Main finding · Duration of hypoglycemic events (<70 mg/dL)Result — go to the resultMM/CIQ ratio 1.15 95% CI 0.10–0.23

Authors' conclusion

In this study, 1 AID system was associated with a longer duration of hypoglycemic events despite similar overall exposure to hypoglycemia.

Study context

Population
Users of automated insulin delivery (AID) with T1D, CGM data over 60 days, active sensor time >70%
Participants
83 vs 65
Exposure
Tandem Control IQ vs MiniMed 780G
  • Control IQ (CIQ)n = 83reference
  • MMn = 65
Outcome
Duration of hypoglycemic events (<70 mg/dL)
Follow-up
60 days

Main finding

As reported in the abstract

MM/CIQ ratio

1.15

95% CI 0.10–0.23

P < 0.001

By group

Observational data: associations, not effects.

Further findings

Duration of hyperglycemic events (>180 mg/dL) · 60 days · no statistically significant difference between systems

MM/CIQ ratio 0.95 (0.86–1.05) · P = 0.33

Median

OutcomeCIQMMP value
Number of hypoglycemic events per 60 days28 (IQR 11–45)23 (IQR 13–40)P = 0.31

Original publication

Distribution of Hypo- and Hyperglycemic Event Duration in Type 1 Diabetes Using Automated Insulin Delivery. J Diabetes Sci Technol. Published 30 July 2026. doi:10.1177/19322968261471164

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.