Continuous Glucose Monitoring Use in Youth with Type 2 Diabetes: A Pilot Randomized Study
Authors' conclusion
CGM was a feasible and acceptable adjunct to diabetes self-care among >50% of Y-T2D prescribed infrequent SMBG monitoring. Unwillingness to wear a device and social stigma impeded device use.
Study context
- Population
- Youth-onset T2D prescribed self-monitoring of blood glucose (SMBG) ≤twice daily; 82% female, 68% Black, 14.9 ± 3.8 years, BMI 36.2 ± 7.7 kg/m², hemoglobin A1c (HbA1c) 7.4 ± 2.4%52 screened eligible
- Participants
- 18 / 10 / 8
- Comparison
- Continuous glucose monitoring (CGM) vs fingerstick monitoring
- CGMn = 18
- Controln = 10reference
- Control-CGMn = 8
- Primary endpoint
- Feasibility (recruitment, study participation and retention >60%) and acceptability (CGM wear time ≥60% at end of study)
- Follow-up
- 12 weeks
Methodological detailspilot, parallel, randomized 2:1, optional 4-week extension (Control-CGM)
- Pilot
- Parallel
- Randomized 2:1
- Optional 4-week extension (Control-CGM)
Further findings
Wear time over study · months 1, 2, 3
- 1st month
- 71 ± 31%
- 2nd month
- 55 ± 32%
- 3rd month
- 38 ± 34%
- Decline over study
- P = 0.003
Glycemia, CGM burden/benefits, diabetes distress scores · baseline to end of intervention
- No significant changes
- P > 0.05
Safety
Minor sensor adhesion adverse events
- Common causes of reduced wear time
- 75%
Original publication
Continuous Glucose Monitoring Use in Youth with Type 2 Diabetes: A Pilot Randomized Study. Diabetes Technol Ther. Published 18 March 2025. doi:10. 1089/ dia. 2024. 0539