Diabetes technology

Accuracy of Continuous Glucose Monitoring in an Insulin-Treated Population Requiring Haemodialysis

J Diabetes Sci TechnolPublished Diagnostic accuracy study

Authors' conclusion

We conclude that the Freestyle Libre sensor is accurate in measuring glucose levels when compared to glucose as measured by capillary SMBG testing and laboratory obtained serum glucose in patients on HD.

Study context

Population
Insulin-treated diabetes patients on haemodialysis (HD)
Participants
69 patients
Comparison
Freestyle Libre Pro continuous glucose monitoring (CGM) vs capillary SMBG and plasma glucose
Outcome
Clarke error grid: glucose values in acceptable range of agreement
Methodological detailsData cleansing applied to account for rapidly correcting hypoglycaemia and poor SMBG technique
  • Data cleansing applied to account for rapidly correcting hypoglycaemia and poor SMBG technique

Performance

As reported in the abstract

Glucose values in acceptable range of agreement (Clarke error grid)

97.9%

On dialysis days

97.3%

On non-dialysis days

99.1%

Further findings

Acceptable agreement (Clarke-error grid), dialysis days vs non-dialysis days

Dialysis days
97.3%
Non-dialysis days
99.1%

Original publication

Accuracy of Continuous Glucose Monitoring in an Insulin-Treated Population Requiring Haemodialysis. J Diabetes Sci Technol. Published 6 May 2023. doi:10.1177/19322968231173447