Type 1 diabetes

Accuracy of Continuous Glucose Monitoring in Adults with Type 1 Diabetes Admitted to Hospital: A Real-World Multicenter Observational Study

Diabetes Technol TherPublished Retrospective observational study

Authors' conclusion

In this real-world multicenter study, CGM glucose agreed well with reference blood glucose, suggesting modern CGM devices could be safely and effectively used in hospitalized adults with T1D.

Study context

Population
Adults with T1D requiring multiday admissions during 2020–2023 across three health services in Australia; dialysis and pediatric/obstetric/palliative care/psychiatry admissions excluded
Participants
146 adults214 admissions
Exposure
Continuous glucose monitoring (CGM) interstitial glucose vs reference blood glucose
Outcome
CGM accuracy vs time-matched (±5 min) reference glucose: median ARD, MARD and consensus error grid analysis
Methodological detailsmulticenter, real-world
  • Multicenter
  • Real-world

Main finding

As reported in the abstract

CGM accuracy, all 2,199 CGM-reference pairs
Overall absolute relative difference (ARD), mean (SD)
12.8% (13.1)
Overall ARD, median (IQR)
9.4% (3.7-17.7)
Glucose pairs within consensus error grid (CEG) zones A/B
99.3%

Observational data: associations, not effects.

Further findings

Mean ARD (MARD)

OutcomeCritical careNoncritical careP value
MARD in critical care vs noncritical care wardsAccuracy lower in critical care16.1%12.0%P < 0.001

Original publication

Accuracy of Continuous Glucose Monitoring in Adults with Type 1 Diabetes Admitted to Hospital: A Real-World Multicenter Observational Study. Diabetes Technol Ther. Published 13 January 2025. doi:10.1089/dia.2024.0604

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.