In‐flight glycaemic control using automated insulin delivery systems: A within‐subject comparative pilot study

Diabetes Obes MetabPublished Within-subject comparative pilot study

Authors' conclusion

AID systems maintained robust glycaemic control and safety during commercial flights, comparable to ground-based conditions. These data support the feasibility of in-flight AIDs use and provide a basis for future regulatory and clinical practice updates. Larger, multicenter studies are needed to generalize findings.

Study context

Population
Adults with T1D using commercial AID (MiniMed780G; Omnipod 5; Control-IQ; CamAPS FX with YpsoPump, n = 5 per system); age 37.9 ± 12.8 years, HbA1c 52.3 ± 4.9 mmol/mol, time in range (TIR) 74 ± 9.8%, diabetes duration 19.25 ± 10.6 years5 per AID system
Participants
20 adults
Comparison
AID use in-flight vs on-ground
  • In-flightn = 20
  • On-groundn = 20reference
Outcome
TIR (3.9-10.0 mmol/L)
Methodological detailswithin-subject comparison, mid-haul commercial flights vs matched ground-based conditions
  • Within-subject comparison
  • Mid-haul commercial flights vs matched ground-based conditions

Main finding

As reported in the abstract

Mean difference

4.6 %

95% CI −5.0- 14.2

By group

Between In-flight and On-ground
mean difference 4.6 % (95% CI −5.0- 14.2)

Further findings

TITR (3.9-7.8 mmol/L)

TAR

TBR

Insulin delivery

Bolus insulin dosing

Insulin delivery

Insulin delivery slightly increased in-flight, driven by bolus dosing

Safety

Episodes of level 2 hypoglycaemia, DKA or device failure
0

Original publication

In‐flight glycaemic control using automated insulin delivery systems: A within‐subject comparative pilot study. Diabetes Obes Metab. Published 22 December 2025. doi:10.1111/dom.70404