Endocrine oncology

Improved Diagnostic Accuracy of Thyroid Fine-Needle Aspiration Cytology with Artificial Intelligence Technology

ThyroidPublished Diagnostic accuracy study

Authors' conclusion

These results suggest that the application of AI technology to thyroid FNA cytology may improve the diagnostic accuracy as well as intra- and inter-observer variability among pathologists.

Study context

Population
Thyroid FNA whole slide images (WSIs) from the Open artificial intelligence (AI) Dataset Project (3 university hospitals and 215 Korean institutions); 306 FNAs (78 malignant [PTC], 228 benign) from 86 institutions used for training10,332 image patches
Participants
306 participants
Comparison
AI model vs expert cytopathologists for thyroid FNA cytology
Outcome
Diagnostic performance, AI vs cytopathologists (1031 randomly selected image patches)
Methodological detailsmulticenter, retrospective
  • Multicenter
  • Retrospective

Performance

As reported in the abstract

Test or modelSensitivitySpecificityAccuracy
Inception ResNet v2
99.81% (95% CI 99.54-100.00%)Sensitivity on a scale from 0 to 100 percent
99.61% (95% CI 99.23-99.99%)Specificity on a scale from 0 to 100 percent
99.71% (95% CI 99.38-100.00%)
Expert cytopathologists
87.26% (95% CI 85.22-89.30%)Sensitivity on a scale from 0 to 100 percent
90.58% (95% CI 88.80-92.36%)Specificity on a scale from 0 to 100 percent
88.91% (95% CI 86.99-90.83%)

Sensitivity

Inception ResNet v299.81% (95% CI 99.54-100.00%)
Expert cytopathologists87.26% (95% CI 85.22-89.30%)
Sensitivity on a scale from 0 to 100 percent

Specificity

Inception ResNet v299.61% (95% CI 99.23-99.99%)
Expert cytopathologists90.58% (95% CI 88.80-92.36%)
Specificity on a scale from 0 to 100 percent

Accuracy

Inception ResNet v299.71% (95% CI 99.38-100.00%)
Expert cytopathologists88.91% (95% CI 86.99-90.83%)

Further findings

OutcomeInception ResNet v2
AI model performance in training, validation and test datasets
Accuracy (training, validation, test)99.7%, 97.7%, 94.9%
Sensitivity (training, validation, test)99.9%, 99.6%, 100%
Specificity (training, validation, test)99.6%, 96.4%, 90.4%
  • AI model performance in training, validation and test datasets: best of 6 pretested AI models

Cytopathologists' performance after reference to AI results

Accuracy of all experts after referring to AI
96%, 95%, and 96%
Diagnostic agreement increased
from 0.64 to 0.84

Original publication

Improved Diagnostic Accuracy of Thyroid Fine-Needle Aspiration Cytology with Artificial Intelligence Technology. Thyroid. Published 24 June 2024. doi:10.1089/thy.2023.0384

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.