Enzymatic 2-Hydroxybutyrate Measurement for Dysglycemia Screening Beyond Conventional Fasting Measures

Diabetes CarePublished Diagnostic accuracy study

Authors' conclusion

Enzymatic 2-HB measurement may serve as a screening biomarker to rule out postprandial dysglycemia in individuals with normal FPG and HbA1c.

Study context

Population
Biomarkers of Personalized Medicine cohort; prespecified subcohort with fasting plasma glucose (FPG) <110 mg/dL and HbA1c <39 mmol/mol (5.7%)534 with normal FPG and HbA1c
Participants
772 participants
Outcome
Incremental discrimination of dysglycemia by fasting 2-HB beyond routine fasting measures; postprandial dysglycemia (2-h glucose >140 mg/dL during OGTT) in subcohort
Methodological detailsprespecified subcohort
  • Prespecified subcohort

Performance

As reported in the abstract

Test or modelAUCSensitivity at 39 µmol/LNPV
2-HB0.7990%98.9%

2-HB

AUC0.79
Sensitivity at 39 µmol/L90%
NPV98.9%

Further findings

OutcomeORP value
Dysglycemia per 1-SD increase in 2-HBIndependently associated2.23P < 0.001

Fasting 2-HB by glycemic status

µmol/L

2-HB in normoglycemia
39.0
2-HB in prediabetes
51.9
2-HB in T2D
57.0
  • n = 772

Original publication

Enzymatic 2-Hydroxybutyrate Measurement for Dysglycemia Screening Beyond Conventional Fasting Measures. Diabetes Care. Published 8 June 2026. doi:10.2337/dc26-0567

Composed by AI from the published abstract and checked against it. How Briefs are made →