Diabetes technology

The Correlation Between Fear and Perceived Frequency of Hypoglycemia and Continuous Glucose Monitoring Metrics in Adults With Type 1 Diabetes Using Diabetes Technology: A 1-Year Analysis

Diabetes CarePublished Retrospective exploratory analysis

Authors' conclusion

In adults using diabetes technology over 12 months, fear and perceived frequency of hypoglycemia showed no clear correlations with CGM metrics, suggesting both are influenced by more than glycemic profiles alone.

Study context

Population
Adults with T1D using rtCGM or hybrid closed-loop for 12 months; baseline mean age 41.0 ± 13.7 years, 55.9% women, diabetes duration 21.6 ± 12.7 years, HbA1c 7.6 ± 1.0%
Participants
1,370 adults
Comparison
ALERTT1 vs INRANGE
  • ALERTT1n = 254
  • INRANGEn = 1,116
Primary endpoint
Correlations between hypoglycemia fear (HFS-worry, HFS-behavior), perceived hypoglycemia frequency (DTSQs-hypo) and CGM metrics
Follow-up
Baseline, 12 months and 12-month change
Methodological detailspooled analysis of ALERTT1 and INRANGE studies, 12-month follow-up
  • Pooled analysis of ALERTT1 and INRANGE studies
  • 12-month follow-up

Primary result

As reported in the abstract

Correlation of HFS-worry, HFS-behavior and DTSQs-hypo with CGM metrics
  • HFS-worry, HFS-behavior and DTSQs-hypo showed no clear correlations with time in hypoglycemia or other continuous glucose monitoring (CGM) metrics at baseline, at 12 months, or over 12-month change

Further findings

Time <3.9 mmol/L · baseline to 12 months

Decreased from 3.4 ± 3.5% to 2.3 ± 2.2% (mean ± SD)

Time <3.0 mmol/L · baseline to 12 months

Decreased from 0.8 ± 1.4% to 0.5 ± 0.7% (mean ± SD)

HFS-worry · baseline to 12 months

Decreased from 21.0 ± 12.9 to 16.8 ± 12.1 (mean ± SD)

DTSQs-hypo · baseline to 12 months

Decreased from 3.3 ± 1.5 to 2.7 ± 1.4 (mean ± SD)

Original publication

The Correlation Between Fear and Perceived Frequency of Hypoglycemia and Continuous Glucose Monitoring Metrics in Adults With Type 1 Diabetes Using Diabetes Technology: A 1-Year Analysis. Diabetes Care. Published 6 July 2026. doi:10.2337/dc26-0763

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.