Diabetes technology

Continuous Glucose Monitor Accuracy for Diabetes Management in Hospitalized Children

Diabetes CarePublished Retrospective cohort study

Authors' conclusion

CGMs demonstrated acceptable accuracy in hospitalized children with diabetes. CGM data should be integrated into hospital electronic records to optimize management.

Study context

Population
Children aged 2–18 years with diabetes admitted to an academic children's hospital, March 2018 to September 2023, with CGM data
Participants
202 children277 admissions
Outcome
CGM accuracy and clinical reliability: MARD and Clarke error grid (CEG) analyses vs POC glucose
Methodological detailssingle-centre
  • Single-centre

Main finding

As reported in the abstract

CGM accuracy vs POC glucose (paired measurements, n = 2,904)
Mean absolute relative difference (MARD)
15.9%
Values in zones A and B of Clarke error grid (CEG)
96.6%
Paired values within 15%/15 mg/dL range
≈62%
Paired values within 20%/20
74%
Paired values within 30%/30
88%

Observational data: associations, not effects.

Further findings

Effect of serum pH, sodium and blood urea nitrogen (BUN) on CGM values or absolute relative difference

Serum pH, sodium and BUN had no impact on CGM values or absolute relative difference (linear regression)

Original publication

Continuous Glucose Monitor Accuracy for Diabetes Management in Hospitalized Children. Diabetes Care. Published 2 December 2024. doi:10.2337/dc24-1562

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.