Diabetes technology

Closed-loop insulin delivery for glycaemic control in hospitalised and perioperative adults: A systematic review and meta-analysis of randomised controlled trials

Diabetes Res Clin PractPublished Systematic review and meta-analysis of randomised controlled trials

Authors' conclusion

Closed-loop insulin delivery may improve glycaemic process measures

Study context

Population
Hospitalised and perioperative adults7 trials, analysed
Participants
375 participants
Comparison
Closed-loop or automated insulin delivery vs usual care or conventional insulin therapy
Outcome
Glycaemic control
Methodological detailsrandom-effects meta-analysis, RoB 2, GRADE
  • Random-effects meta-analysis
  • RoB 2
  • GRADE

Pooled result

As reported in the abstract

Closed-loop vs Usual careDifference in time in target glucose range, percentage points (95% CI)
I2 = 0%; moderate certainty
23.91(19.40–28.43)
I2 = 36.3%; moderate certainty
reduction in mean glucose 1.79 mmol/L (95% CI 1.06 to 2.53 lower)

Further pooled results

Clinically significant hyperglycaemia

2 trials (69 participants); both estimates favoured closed-loop; exploratory and imprecise

Safety

Events

OutcomeClosed-loopUsual care
Severe hypoglycaemiaPrecluding reliable estimation of comparative safety00

Original publication

Closed-loop insulin delivery for glycaemic control in hospitalised and perioperative adults: A systematic review and meta-analysis of randomised controlled trials. Diabetes Res Clin Pract. Published 25 August 2026. doi:10.1016/j.diabres.2026.113519

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.