Methodological details expert consensus panel Recommendations As issued by the authors
51 recommendations voted on; classified as strong (43) or mild (8)
Reference
Issued by Diabetes Technology Society expert consensus panel
Document Consensus statement
Scope Metrics for research on CGM use in the hospital setting (inpatient clinical trials), across 10 dimensions: hospital hypoglycemia, hyperglycemia, time in range, glycemic variability, glycemia risk index, CGM accuracy and reference methods, time blocks for glycemic goals, CGM data sufficiency, CGM data for insulin dosing, miscellaneous factors Authors Spanakis EK, Cook CB, Kulasa K, Aloi JA, Bally L, Davis G, et al.All 17 authors Spanakis EK, Cook CB, Kulasa K, Aloi JA, Bally L, Davis G, Dungan KM, Galindo RJ, Mendez CE, Pasquel FJ, Shah VN, Umpierrez GE, Aaron RE, Tian T, Yeung AM, Huang J, Klonoff DC
Published 17 Aug 2023
Original publication A Consensus Statement for Continuous Glucose Monitoring Metrics for Inpatient Clinical Trials. J Diabetes Sci Technol . Published 17 August 2023. doi:10. 1177/ 19322968231191104 Composed by AI from the published abstract and checked against it. How Briefs are made →