Pituitary & hypothalamus

The Time of the Hypertonic Saline Infusion Test for the Diagnosis of Arginine Vasopressin (AVP) Deficiency Can Be Shortened With LC-MS/MS

J Clin Endocrinol MetabPublished Diagnostic accuracy study

Authors' conclusion

LC-MS/MS demonstrated superior diagnostic accuracy for AVP-D at 90 minutes of HST, indicating that the HST time can be shortened from 120 to 90 minutes by measuring AVP with LC-MS/MS.

Study context

Population
16 patients with AVP deficiency (AVP-D) and 28 controls undergoing hypertonic saline infusion test (HST)16 AVP-D, 28 controls
Comparison
LC-MS/MS vs radioimmunoassay (RIA) for plasma AVP measurement during HST
Outcome
Diagnostic accuracy (ROC analysis) of regression gradients of serum sodium vs plasma AVP for AVP-D
Follow-up
90 and 120 minutes

Performance

As reported in the abstract

Diagnosis of AVP-D · 90 minutes
Test or modelAUCSensitivitySpecificity
LC-MS/MS0.97 (95% CI, 0.83-1.00)100%96%
RIA0.93 (95% CI, 0.80-0.98)100%81%

AUC

LC-MS/MS0.97 (95% CI, 0.83-1.00)
RIA0.93 (95% CI, 0.80-0.98)

Sensitivity

LC-MS/MS100%
RIA100%

Specificity

LC-MS/MS96%
RIA81%

Further findings

Sensitivity and specificity · 120 minutes

Sensitivity or specificity did not differ between the 2 methods

Original publication

The Time of the Hypertonic Saline Infusion Test for the Diagnosis of AVP Deficiency Can Be Shortened With LC-MS/MS. J Clin Endocrinol Metab. Published 30 July 2025. doi:10.1210/clinem/dgaf432