Multicenter Comparison of Computerized Insulin Sensitivity Coefficient and Paper-Based Intravenous Insulin Protocols

J Diabetes Sci TechnolPublished Pre-post intervention study

Authors' conclusion

A computerized ISC-based insulin infusion protocol resulted in more blood glucose values in target range and lower rates of hypoglycemia compared with paper-based protocols.

Study context

Population
Critically ill adults initiated on intravenous (IV) insulin infusion, 13 institutions
Participants
237 vs 207
Comparison
Computerized insulin sensitivity coefficient (ISC)-based insulin infusion calculator protocol vs paper-based IV insulin infusion protocols
  • Post-interventionn = 237
  • Pre-interventionn = 207reference
Outcome
Percentage of blood glucose levels within target range (80-180 mg/dL)
Methodological detailsmulticentre, 13 institutions
  • Multicentre
  • 13 institutions

Main finding

As reported in the abstract

Blood glucose values in range (80-180 mg/dL)
GroupValueBlood glucose values
Pre-intervention73%6313
Post-intervention78.3%7870

Value

Pre-intervention73%
Post-intervention78.3%

Blood glucose values

Pre-intervention6313
Post-intervention7870
  • Post-intervention vs Pre-intervention: P < 0.01

Secondary outcomes

Hyperglycemia (>200 mg/dL)

P < 0.01

Severe hyperglycemia (>250 mg/dL)

P < 0.01

Safety

Hypoglycemia (<70 mg/dL)

P < 0.01

Severe hypoglycemia (<54 mg/dL)

P = 0.24

Severe hypoglycemia (<54 mg/dL)

There was no difference in severe hypoglycemia

Original publication

Multicenter Comparison of Computerized Insulin Sensitivity Coefficient and Paper-Based Intravenous Insulin Protocols. J Diabetes Sci Technol. Published 15 July 2026. doi:10.1177/19322968261462502

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.