Improving the Bias of Comparator Methods in Analytical Performance Assessments Through Recalibration

J Diabetes Sci TechnolPublished Methodological study

Authors' conclusion

Recalibration did lead to a decrease in bias and thus can reduce the impact of the choice of comparator method. The procedure should be verified in a prospectively designed setting.

Study context

Population
Existing data from performance studies of continuous and blood glucose monitoring systems
Exposure
Bias between devices before vs after recalibration
Outcome
Bias between devices before and after recalibration
Methodological detailsretrospective analysis of existing performance-study data
  • Retrospective analysis of existing performance-study data

Main finding

As reported in the abstract

Higher-order method recalibration, data set 1: bias before → after

−3.6% to +0.6%

Higher-order method recalibration, data set 2: bias before → after

+11.0% to +0.3%

Higher-order materials (SRM) recalibration, data set 1: bias before → after

−3.1% to −0.1%

Higher-order materials (SRM) recalibration, data set 2: bias before → after

−4.3% to −2.7%

Observational data: associations, not effects.

Original publication

Improving the Bias of Comparator Methods in Analytical Performance Assessments Through Recalibration. J Diabetes Sci Technol. Published 22 October 2022. doi:10.1177/19322968221133107