Thyroid disease

CT-Free Quantitative Thyroid Single-photon Emission Computed Tomography (SPECT) Based on Artificial Intelligence: A Prospective Multicenter Noninferiority Clinical Trial

ThyroidPublished Diagnostic accuracy study

Authors' conclusion

CT-free SPECT using AI demonstrated noninferior diagnostic performance for thyrotoxicosis compared with conventional hybrid imaging while reducing radiation exposure and analysis time.

Study context

Population
Patients with thyrotoxicosis from three tertiary referral hospitals; 84 GD, 45 indeterminate disease, 23 thyroiditis
Participants
152 patients
Comparison
Computed tomography (CT)-free thyroid SPECT using artificial intelligence (AI) vs conventional SPECT/CT
Outcome
Diagnostic accuracy for GD
Methodological detailsprospective, multicenter, noninferiority clinical trial
  • Prospective
  • Multicenter
  • Noninferiority clinical trial

Performance

As reported in the abstract

Test or modelAccuracy
CT-free SPECT86.2%
SPECT/CT85.5%

Accuracy

CT-free SPECT86.2%
SPECT/CT85.5%
  • CT-free SPECT vs SPECT/CT: lower CI bound −3.0% — lower CI bound −3.0%

Secondary outcomes

Time to generate technetium thyroid uptake (TcTU) values

CT-free SPECT automatically generated TcTU values more quickly than SPECT/CT (40 minutes vs. 4 minutes)

Safety

Radiation exposure

Radiation exposure — Reduction of radiation exposure with omission of CT
33.5%

Original publication

CT-Free Quantitative Thyroid SPECT Based on Artificial Intelligence: A Prospective Multicenter Noninferiority Clinical Trial. Thyroid. Published 7 April 2026. doi:10.1177/10507256261440401