Pituitary & hypothalamus

Clinical performance of an IGF1 LC-MS/MS assay and associated normative dataset in routine endocrinology

Eur J EndocrinolPublished Diagnostic accuracy study

Authors' conclusion

Our LC-MS/MS IGF1 assay integrated with its own population-based normative dataset demonstrated superior alignment with clinical assessment compared with LBA results. In our setting, this method provides a clinically reliable benchmark for IGF1 interpretation and may serve as a reference for IGF1 harmonization and broader adoption of the Lifelines normative dataset in routine endocrinology.

Study context

Population
Paired IGF-1 results in routine endocrinology, adult and pediatric groupspaired IGF-1 results
Participants
2,057 participants
Comparison
In-house LC-MS/MS IGF-1 assay with method-matched Lifelines normative dataset vs IDS iSYS ligand-binding assays (LBA)
Outcome
Agreement and clinical validity of IGF-1 SDS
Methodological detailsmethod comparison, paired samples
  • Method comparison
  • Paired samples

Performance

As reported in the abstract

Proportional bias

−27%

LC-MS/MS vs IDS iSYS

Weighted Cohen's κ

0.39

Between LC-MS/MS and IDS iSYS · categorical agreement fair

Original publication

Clinical performance of an IGF1 LC-MS/MS assay and associated normative dataset in routine endocrinology. Eur J Endocrinol. Published 27 February 2026. doi:10.1093/ejendo/lvag040

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.